​FLIR Systems, Inc. designs, develops, manufactures, markets, and distributes technologies that enhance perception and awareness. 

FLIR bring innovative sensing solutions into daily life through their thermal imaging systems, visible-light imaging systems, locator systems, measurement and diagnostic systems, and advanced threat detection systems. 

Today FLIR advanced systems and components are used for a wide variety of thermal imaging, situational awareness, and security applications, including airborne and ground-based surveillance, condition monitoring, navigation, recreation, research and development, manufacturing process control, search and rescue, drug interdiction, transportation safety and efficiency, border and maritime patrol, environmental monitoring, and chemical, biological, radiological, nuclear, and explosives threat detection.

About FLIR

A300/A310

​FLIR A300/A310 infrared cameras target safety and automation applications where networking capabilities and compliance with networking protocols is of essence.

The infrared cameras can be installed discretely almost anywhere to monitor your business and are ideal for any industry where fire prevention, critical vessel monitoring and fixed-mounted predictive maintenance are important. Typical users are oil refineries, petrochemical and power plants, and for natural gas processing for monitoring of substations and warehouses.

In all industries the possibility to automatically ensure quality and to prevent and detect fires is of vital importance. The solution can be a fixed infrared camera that monitors your process or asset continuously, detecting minute temperature differences in a 24/7 manner. This methodology has been implemented in a wide range of industrial automation applications all around the world.

FLIR thermal imagers offer affordable, fully integrated thermal imaging and measurement solutions for applications such as process development and optimization, industrial process monitoring, product verification, quality assurance, safety applications and more. An infrared camera can detect even small temperature differences in most operating conditions, including when there is smoke, fog or steam involved in the measurement situation.

FLIR A300/A310 infrared cameras target safety and automation applications where networking capabilities and compliance with networking protocols is of essence. The infrared cameras can be installed discretely almost anywhere to monitor your business and are ideal for any industry where fire prevention, critical vessel monitoring and fixed-mounted predictive maintenance are important. Typical users are oil refineries, petrochemical and power plants, and for natural gas processing for monitoring of substations and warehouses.

Standard Key Features

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • Open and well-described TCP/IP protocol for control and set-up

FLIR A300

FLIR A310

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • Open and well-described TCP/IP protocol for control and set-up
  • 16-bit 320 × 240 images @ 3 Hz, radiometric
  • Lenses: 25° included, 15° and 45° optional

     
  • Support for EthernetIP field bus protocol (analyse, alarm, and simple camera control)
  • Support for Modbus TCP field bus protocol (analyse, alarm, and simple camera control)
  • Built-in extensive analysis functionality
  • Extensive alarm functionality, as a function of analysis and more
  • On schedule: file sending (FTP) or email (SMTP) of analysis results or images
  • On alarms: file sending (FTP) or email (SMTP) of analysis results or images
  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • Open and well-described TCP/IP protocol for control and set-up
  • 16-bit 320 × 240 images @ 7–8 Hz, radiometric
  • Lenses: 25° included, 15° and 45° optional

Model Number

FLIR A300 A300

FLIR A310 A310

Imaging & Optical Data

Field of View (FOV) / Minimum Focus Distance 25° × 18.8° / 0.4 m
Lens Identification Automatic
Thermal Sensitivity < 0.05°C at +30°C / 50 mK
Foucs Automatic or manual
F-Number 1.3
Image Frequency - NTSC & MPEG4 30 Hz
Lens Options Standard: 25° × 19°; Optional: 90°, 45°, 15°, 6°
Zoom 1–8× continuous, digital, interpolating zooming on images

Detector Data

IR Resolution 320 × 240 pixels
Detector Pitch 25 μm
Detector Time Constant Typical 12 ms
Focal Plane Array (FPA) / Spectral Range Uncooled Microbolometer / 7.5–13 μm

Measurement Analysis

Object Temperature Range –20 to +120°C
0 to +350°C
High Temp Option Up to 3,632°F (2,000°C)
Accuracy ±2°C or ±2% of reading
Spotmeter N/A 10
Area N/A 10 boxes with max./min./average/position
Isotherm N/A 1 with above/below/interval
Measurement Option N/A Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Difference Temperature N/A Delta temperature between measurement functions or reference temperature
Reference Temperature N/A Manually set or captured from any measurement function
Atmospheric Transmission Correction N/A Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics Transmission Correction N/A Automatic, based on signals from internal sensors
Emissivity Correction N/A Variable from 0.01 to 1.0
Reflected Apparent Temperature Correction N/A Automatic, based on input of reflected temperature
External Optics/Windows Correction N/A Automatic, based on input of optics/window transmission and temperature
Measurement Corrections N/A Global and individual object parameters

Alarm

Alarm Functions N/A 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output N/A Digital Out, log, store image, file sending (ftp), email (SMTP), notification

Set-Up

Color Palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up Commands Date/time, Temperature°C
Storage of Images
Image Storage Types Built-in memory for image storage
File Formats Standard JPEG, 16-bit measurement data included

Composite Video

Video Composite video output, PAL and NTSC compatible
Video, Standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)

Digital Input/Output

Digital Input 2 opto-isolated, 10–30 VDC
Digital Output, Purpose As function of ALARM, Output to ext. device (programmatically set)
Digital Output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, Isolation Voltage 500 VRMS
Digital I/O, Supply Voltage 12/24 VDC, max 200 mA
Digital I/O, Connector Type 6-pole jackable screw terminal
Digital Input, Purpose Image tag (start/stop/general), Input ext. device (programmatically read)

Ethernet

Ethernet Control and image Control, result and image
Ethernet, Protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet, Image Streaming 16-bit 320 x 240 pixels at 3 Hz
- Radiometric
16-bit 320 x 240 pixels at 7-8 Hz
- Radiometric
Ethernet, Type 100 Mbps
Ethernet, Standard IEEE 802.3
Ethernet, Connector Type RJ-45
Ethernet, Type 100 Mbps
Ethernet, Communication TCP/IP socket-based FLIR proprietary
Ethernet, Video Streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Ethernet, Power Power over Ethernet, PoE IEEE 802.3af class 0

Power System

External Power Operation 12/24 VDC, 24 W absolute max
External Power, Connector Type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC

Environmental Data

Operating Temperature Range 5°F to 122°F (-15°C to 50°C)
Storage Temperature Range -40°F to 158°F (-40°C to 70°C)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC EN 61000-6-2:2001 (Immunity) 
EN 61000-6-3:2001 (Emission)
FCC 47 CFR Part 15 Class B (Emission)
Vibration / Bump 2 g (IEC 60068-2-6) / 25 g (IEC 60068-2-29)
Encapsulation IP 40 (IEC 60529)

Physical Data

Housing Material Aluminium
Camera Size (L × W × H) 170 × 70 × 70 mm
Weight 0.7 kg
Tripod Mounting UNC ¼"-20 (on three sides)
Base Mounting 2 × M4 thread mounting holes (on three sides)